Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 234-842-7 | CAS number: 12036-22-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Administrative data
First-aid measures
Inhalation:
If inhaled, remove to fresh air.
If not breathing, give artificial respiration.
If breathing is difficult, give oxygen.
Call a physician immediately.
Skin contact:
In case of skin contact, wash affected areas with soap and water.
Wash clothing and shoes before reuse.
Get medical attention if irritation develops or persists.
Eye contact:
In case of contact, flush eyes with plenty of lukewarm water.
Get medical attention if irritation develops or persists.
Ingestion:
Rinse mouth with plenty od water, drink water for dilution.
Never give anything by mouth to an unconscious person.
Call a physician immediately.
Fire-fighting measures
Fire fighting
Suitable extinguishing media:
- Extinguishing methods depends upon fire in vicinity.
- The product itself does not burn.
Unsuitable extinguishing media: None known.
Further information: None known.
Protective equipment and precautions for firefighters
- Specific hazards during fire fighting: None known.
- Special protective equipment for fire-fighters: In the event of fire, wear self-contained breathing apparatus.
Accidental release measures
Personal precautions:
- Avoid generation of dust.
- If dust is generated, use appropriate respiratory protection.
Environmental precautions:
No special environmental protection measures are necessary.
Claening procedure:
- Pick up mechanically.
- Avoid generation of dust.
- Fill in firmly sealable and labeled containers.
Handling and storage
Handling:
- Avoid genration of dust.
- Vent storage bins, conveyors, dust collectors, ground handling equipment, etc.
- Comply with relevant workplace threshold limit values (AGW) and/or other limit values.
Advice on protection against fire and explosion: No special precautions required.
Storage - Requirements for storage areas and containers:
- No special precautions required.
- Store in a dry place and keep container closed when not in use.
- Information on storage with other products: No special measures necessary
- VCI storage category 13: non-flammable solid materials
Transport information
Land transport (UN RTDG/ADR/RID)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Not dangerous goods
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Not dangerous goods
Air transport (UN RTDG/ICAO/IATA)
Shippingopen allclose all
Special provisions / remarks
- Remarks:
- Not dangerous goods
SpecialProvisionsopen allclose all
Exposure controls / personal protection
Hygiene measures:
Follow usual safety procedures for handling chemicals. Store work clothes separately.
Hand protection:
Glove material: Butyl-rubber, Natural rubber, Nitrile rubber
The data about break through time/strength of material is not valid for undissolved solids/dust.
Body protection: Protective suit
Eye protection: Protective goggles
Respiratory protection: Use respiratory equipment with particle filter, type EN 143
No specific exposure limit value (OEL, EU)
Stability and reactivity
Conditions to avoid: None known.
Materials to avoid: None known.
Thermal decomposition: not applicable
Hazardous decomposition products: not applicable
Disposal considerations
Disposal should be in accordance with applicable state, federal and local laws and regulations. Local regulations may be more stringent than state or federal requirements.
A waste key according to the European waste cataloigue cannot be attributed to the substance as the waste key depends on substance use by the downstream user / consumer.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.