Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study, GLP status not known. Minor restrictions in design and/or reporting but otherwise adequate for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002
Report Date:
2002

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: DIN 51007
Deviations:
not specified
GLP compliance:
not specified

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of test material (as cited in study report): 30948/25/1 C6-Acetal

Results and discussion

Any other information on results incl. tables

First exothermic reaction
Onset temperature of 190 °C
Peak temperature of 250 °C
Released amount of heat 1170 J/g
There was no evidence that a self-accelerating reaction took place.


Second exothermic reaction
Onset temperature of 320 °C
Peak temperature of 364 °C.
Released amount of heat 80 J/g

Applicant's summary and conclusion