Registration Dossier

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study, GLP status not known. Minor restrictions in design and/or reporting but otherwise adequate for assessment

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996
Report Date:
1996

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: DIN 51562
GLP compliance:
not specified
Type of method:
capillary viscometer (static)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
- Name of the test substance used in the study report: C6- Acetal

Results and discussion

Viscosityopen allclose all
Temp.:
other: 5.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.5
Temp.:
other: 50.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.2
Temp.:
other: 100.0°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
0.62

Applicant's summary and conclusion