Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report Date:
2008

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
< 0 hPa
Remarks on result:
other: see also Conclusions

Applicant's summary and conclusion

Conclusions:
Vapour pressure values were calculated as conservative estimates, based on a lack of any detectable vapour pressure up to 150°C and the detection limit of the method, i.e. 10exp-5 hPa: 20°C: << 1.0 x 10exp-7 hPa; 25°C: << 1.0 x 10exp-7 hPa; 50°C: << 1.0 x 10exp-7 hPa