Registration Dossier

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1992
Report Date:
1992

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 84/449/EWG, A.16
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Auto-ignition temperature (liquids / gases)
Remarks on result:
other: No self ignition up to the melting point (196 deg)
Relative self-ignition temperature (solids)
Remarks on result:
other: No self ignition up to the melting point (196 deg)

Applicant's summary and conclusion