Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1992
Report Date:
1992

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: 84/449/EWG, A.4 (vapour pressure balance)
GLP compliance:
yes
Type of method:
effusion method: vapour pressure balance

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
25 °C
Vapour pressure:
0 Pa
Temp.:
50 °C
Vapour pressure:
0 Pa
Temp.:
100 °C
Vapour pressure:
0 Pa

Applicant's summary and conclusion