Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 06, 1996 to January 27, 1997
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study (OECD 209) with acceptable restrictions.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997
Report date:
1997

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method C.11 (Biodegradation: Activated Sludge Respiration Inhibition Test)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 8192 (Water quality - Test for inhibition of oxygen consumption by activated sludge for carbonaceous and ammonium oxidation)
Deviations:
no
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
102822-64-0
Cas Number:
102822-64-0
IUPAC Name:
102822-64-0
Test material form:
solid: particulate/powder
Remarks:
migrated information: powder
Details on test material:
Name: G-7-ACS Mono-Na-Salz
Lot: Op 1/96 vom 28.02.1996

Sampling and analysis

Analytical monitoring:
yes

Test solutions

Vehicle:
yes
Details on test solutions:
Stock solution:
Amount of test item: 2.00 g in 700 ml very clean water
Stirring time: 16.5 hours
Temperature: 23-25°C
pH value after stirring: 3.7
pH was adjusted to 5.6
The clear solution was filled up to 1000 mL.
Concentration of the stock solution: 2000 mg/L
Amount of stock solution used for the test: 500 ml/L
Highest testing concentration 1000 mg/L

Test organisms

Test organisms (species):
activated sludge of a predominantly domestic sewage
Details on inoculum:
Source: Sewage cleaning plant of the city Frankfurt am Main in Sindlingen
Type: washed activated sludge of a communal sewage plant
Test amount: 450 ml/L sludge suspension
Solid content: 3.56 g/L (dry substance)
Content in the end test volume: 1.6 g/L (dry substance)
Acclimatization status: Not acclimatized to the test item and reference substance

Study design

Test type:
not specified
Water media type:
freshwater
Limit test:
yes
Total exposure duration:
3 h

Test conditions

Test temperature:
20.5-21.0°C
pH:
pH of the culture solution: 7.1-7.3 before incubation
Dissolved oxygen:
5.3-5.4mg O2/L
Nominal and measured concentrations:
nominal 1000 mg/L and measured 992.2 mg/L at start of the test and measured 987.9 mg/L at end of the test
Reference substance (positive control):
yes
Remarks:
3,5-Dichlorphenol (5, 20 and 30 mg/L)

Results and discussion

Effect concentrationsopen allclose all
Duration:
3 d
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 d
Dose descriptor:
other: EC20
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Duration:
3 d
Dose descriptor:
other: EC80
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate
Details on results:
From the measured inhibition values the EC values could be determined. Up to the highest test concentration no significent inhibition occurred.
Results with reference substance (positive control):
EC50 of 3,5-Dichlorphenol: 11.8 mg/L

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
Up to the highest test concentration of 1000 mg/L no significent inhibition occurred. Therefore all EC values, EC20, EC50 and EC80 are above 1000 mg/L.