Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to
Guideline:
EPA OPPTS 830.6315 (Flammability)
Deviations:
no
Qualifier:
according to
Guideline:
other: UN Manual Test Methods 32.4
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
impurity
Specific details on test material used for the study:
Batch no.: 18030042
Appearance: colorless to pale yellow liquid
Purity: 99% (GC)
Homogeneity: homogeneous
Production date: 14. Mar. 2018
Expiry date: 14. Mar. 2019
Storage: Room Temperature (20 ± 5°C) store under inert gas in the dark

Results and discussion

Flash point
Key result
Flash point:
ca. 113.5 °C
Atm. press.:
ca. 101 325 Pa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
According to EU Method A.9, OPPTS 830.6315 and UN Manual Test Methods 32.4, the flash point of the test item is 113.5°C at standard pressure.