Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
documentation insufficient for assessment
Justification for type of information:
Tests were carried out using sieves with precise mesh sizes.
no guideline was followed
Qualifier:
equivalent or similar to guideline
Guideline:
other: Sieve with appropriate Mesh size
Principles of method if other than guideline:
Tests were carried out using sieves with precise mesh sizes.
GLP compliance:
no
Type of method:
sedimentation (gravitational settling)
Type of particle tested:
aggregate
Type of distribution:
mass based distribution
Mass median aerodynamic diameter:
> 10 - < 200 µm
Percentile:
D10
Mean:
< 30 µm
St. dev.:
0
Remarks on result:
other: single measure
Percentile:
D50
Mean:
< 63 µm
St. dev.:
0
Remarks on result:
other: single measure
Percentile:
D90
Mean:
< 125 µm
St. dev.:
0
Remarks on result:
other: single measure

D10 <30 µm

D50 < 63 µm

D90 < 125 µm

Conclusions:
The substance particle size distribution was measured bu sieves and the results are:
D10 <30 µm
D50 < 63 µm
D90 < 125 µm

Description of key information

D10 <30 µm

D50 < 63 µm

D90 < 125 µm

Additional information

The substance particle size distribution was measured bu sieves and the results are:

   D10 <30 µm

   D50 < 63 µm

   D90 < 125 µm