Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
May 2017 - December 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2020

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
C.I. Solvent Red 119
EC Number:
602-676-8
Cas Number:
12237-27-3
Molecular formula:
C32H22N10O8Cr
IUPAC Name:
C.I. Solvent Red 119
impurity 1
Reference substance name:
Unknown impurities
Cas Number:
not available
IUPAC Name:
Unknown impurities
impurity 2
Chemical structure
Reference substance name:
Water
EC Number:
231-791-2
EC Name:
Water
Cas Number:
7732-18-5
Molecular formula:
H2O
IUPAC Name:
water
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
>= 4 min

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test item Solvent Red 119 was used in its initial form. The test item could be ignited for the very short time (less as 4 minutes), but then no further burning or smouldering was observed. At the end of the meas-urement the test item was black and melted.
Therefore, the test item is considered to be not flammable.
Executive summary:

The test item Solvent Red 119 was used in its initial form. The test item could be ignited for the very short time(less as 4 minutes),but then no further burning or smouldering was observed. At the end of the measurement the test item was black and melted.