Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
not specified
GLP compliance:
no
Type of method:
microscopic examination
Type of particle tested:
aggregate
Type of distribution:
mass based distribution

Test material

Constituent 1
Reference substance name:
Unknown 6
IUPAC Name:
Unknown 6
Constituent 2
Reference substance name:
Unknown 7
IUPAC Name:
Unknown 7
Constituent 3
Reference substance name:
Unknown 5
IUPAC Name:
Unknown 5
Constituent 4
Reference substance name:
Unknown 4
IUPAC Name:
Unknown 4
Constituent 5
Reference substance name:
Unknown 3
IUPAC Name:
Unknown 3
Constituent 6
Reference substance name:
Unknown 2
IUPAC Name:
Unknown 2
Constituent 7
Reference substance name:
Unknown 1
IUPAC Name:
Unknown 1
Test material form:
solid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 1187902
- Expiration date of the lot/batch: Not specified

Results and discussion

Mass median aerodynamic diameter:
ca. 24.5 µm
Particle sizeopen allclose all
Key result
Percentile:
D10
Mean:
ca. 10 µm
St. dev.:
0.41
Key result
Percentile:
D50
Mean:
ca. 24 µm
St. dev.:
0.51
Key result
Percentile:
D90
Mean:
ca. 57 µm
St. dev.:
2.8

Any other information on results incl. tables

The particle size distribution curve and cumulative frequency curve for the sample are attached as background material below.

Applicant's summary and conclusion

Conclusions:
A particle size mono-modal distribution with X50 (Dv50) of 24.5 microns was obtained.
Executive summary:

The particle size of a sample of Escherichia Coli dehalogenase catalyst was determined by laser diffraction. X10, X50 and X90 values of 10µm, 24µm and 57µm respectively were obtained with a mono-modal distribution with X50 (Dv50) of 24.5 µm.