Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28.03.2007-08.05.2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU guidelines and GLP principles.
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. certificate)
Type of method:
effusion method: vapour pressure balance
Temp.:
20 °C
Vapour pressure:
0 Pa
Temp.:
25 °C
Vapour pressure:
0.001 Pa
Temp.:
50 °C
Vapour pressure:
0.033 Pa
Executive summary:

The vapour pressure of the test substance is 0.00037 Pa at 20°C.

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information