Registration Dossier

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06.06.2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EU guidelines and GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report Date:
2007

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: In a pre-test the test substance could not be ignited, but melted

Applicant's summary and conclusion

Executive summary:

In a pre-test the test substance could not be ignited. Hence the substance is not highly flammable.