Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26 February 2018 to 29 August 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Test material form:
liquid: viscous
Specific details on test material used for the study:
- Physical Form: Brown viscous liquid to paste
- Purity: 99.9 %

Results and discussion

Auto-ignition temperature (liquids / gases)
Key result
Auto-ignition temperature:
437 °C
Atm. press.:
101.8 kPa

Applicant's summary and conclusion

Conclusions:
The auto flammability of the test substance has been determined to be 437 °C.

Executive summary:

In a study performed to the standardised guideline EU Test Method A.15 under GLP conditions, the auto flammability of the test substance has been determined to be 437 °C.