Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-10-29
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: The substance can be ignited locally by the hot flame of a small gas burner, but went out after removal of the external flame.

The substance can be ignited locally by the hot flame of a small gas burner, but went out after removal of the external flame. Therefore the substance is not a flammable solid of class 4.1 and the full burning rate test is therefore not required.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item is not classified as a flammable solid.
Executive summary:

The substance can be ignited locally by the hot flame of a small gas burner, but went out after removal of the external flame. The test item is therefore not classified as a flammable solid of class 4.1.

Description of key information

The test item is not classified as a flammable solid.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

During the preliminary screening test, the substance can be ignited locally by the hot flame of a small gas burner, but went out after removal of the external flame. The test item is therefore not classified as a flammable solid of class 4.1.