Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures

General advice :

Do not leave the victim unattended.

If inhaled :

If unconscious, place in recovery position and seek medical advice.

If symptoms persist, call a physician.

In case of skin contact :

Take off contaminated clothing and shoes immediately.

If on skin, rinse well with water.

In case of eye contact :

Remove contact lenses.

Immediately flush eyes for at least 15 minutes. Get medical attention.

If swallowed :

Keep respiratory tract clear.

Do not give milk or alcoholic beverages.

Never give anything by mouth to an unconscious person.

If symptoms persist, call a physician.

Fire-fighting measures

Firefighting measures

Extinguishing media

Suitable extinguishing media :

Dry chemical

Alcohol-resistant foam

Carbon dioxide (CO2)

Water spray

Unsuitable extinguishing media: no data available

Special hazards arising from the substance or mixture

Specific hazards during firefighting: no data available

Advice for firefighters

Special protective equipment for firefighters : Wear self-contained breathing apparatus for firefighting if necessary.

Further information :

Standard procedure for chemical fires.

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

Personal precautions : no data available

Environmental precautions

Environmental precautions :

Prevent product from entering drains.

If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and materials for containment and cleaning up

Methods for cleaning up :

Wipe up with absorbent material (e.g. cloth, fleece).

Keep in suitable, closed containers for disposal.

Handling and storage

Precautions for safe handling

Advice on safe handling:

Smoking, eating and drinking should be prohibited in the application area.

Advice on protection against fire and explosion:

Normal measures for preventive fire protection.

Temperature class : no data available

Fire-fighting class : no data available

Dust explosion class : no data available

Conditions for safe storage, including any incompatibilities

Requirements for storage areas and containers:

Electrical installations / working materials must comply with

the technological safety standards.

Further information on storage conditions:

Ambient / 10-30°C (50-85°F)

Preferably full, hermetically sealed

Advice on common storage : no data available

German storage class : no data available

Other data : No decomposition if stored and applied as directed.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
N/A
Shippingopen allclose all
Labels:
Not regulated as a dangerous good
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
N/A
Shippingopen allclose all
Labels:
Not regulated as a dangerous good
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
N/A
Shippingopen allclose all
Labels:
Not regulated as a dangerous good
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
N/A
Shippingopen allclose all
Labels:
Not regulated as a dangerous good
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters

Contains no substances with occupational exposure limit values.

Exposure controls

Personal protective equipment

Respiratory protection :

Use only in well-ventilated areas.

In case a risk analysis proved the cartridge respirator as

acceptable, use type: ABEK-P3 (EN 14387)

respirator cartridges as a backup to engineering controls.

In absence of engineering controls, use self-contained

breathing apparatus or full face supplied air respirators.

Use respirators and components tested and approved under

appropriate government standards such as CEN (EU).

Hand protection :

Use gloves when handling substance in open systems.

Inspect gloves prior to use. Train operators for proper use.

If only incidental exposure is expected: (work without direct

contact to substance) use gloves tested according EN 16523-

1 breakthrough times at least 10 minutes, tested for chemicals

indicated in chapter 3 of this SDS. Change gloves frequently.

If direct skin contact is expected: use gloves tested according

to EN 16523-1, tested for chemicals indicated in chapter 3 of

this SDS. Permeation time must exceed contact time.

Eye protection :

Use tightly fitting safety glasses according to EN 166.

Skin and body protection :

Wear working clothes covering arms and legs.

The type of protective equipment must be selected according

to the concentration and amount of the dangerous substance

at the specific workplace. Use apron or complete chemical suit

if exposure is expected.

Hygiene measures :

Do not eat, drink or smoke during work.

Wash and dry hands after finished working.

Protective measures :

Exposure assessment: Exposure is dependent on the product

being handled, the potential for chemical release, and any

resulting airborne concentrations or dermal contact. Since

product handling and release scenarios vary, and no two

workplaces are exactly alike, it is recommended that the

potential for exposure be assessed prior to the product’s use

or introduction. Exposure assessments should be performed

by an occupational hygienist, industrial hygienist, or other

qualified occupational or environmental health professional.

An exposure assessment should be conducted to determine

the efficacy of any ventilation and the need for additional

respiratory protection.

PPE is always the last resort to avoid exposure. In any case

technical and organisational measures have to be explored

and used prior to the selection of PPE. The PPE selection is

for operators trained to work with chemicals according to good

industrial hygiene and safety practice. Operators have to be

trained and used to PPE handling.

Environmental exposure controls

General advice :

Prevent product from entering drains.

If the product contaminates rivers and lakes or drains inform respective authorities.

Stability and reactivity

Reactivity

none

Chemical stability

The product is chemically stable.

Possibility of hazardous reactions

Hazardous reactions : Stable under recommended storage conditions., No hazards to be specially mentioned.

Conditions to avoid

Conditions to avoid : no data available

Incompatible materials

Materials to avoid : no data available

Hazardous decomposition products

Hazardous decomposition products: no data available

Thermal decomposition : no data available

Disposal considerations

Waste treatment methods

Contaminated packaging : Empty containers should be taken to an approved waste handling site for recycling or disposal.

Dispose of in accordance with local regulations.