Registration Dossier

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report Date:
2017

Materials and methods

Test guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
flask method

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Test material form:
liquid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Siltech Corp Silquat A0 (3670-11510011)
- Expiration date of the lot/batch: 2018-11-05
- Purity test date: 2015-11-05

Results and discussion

Water solubility
Key result
Water solubility:
> 250 g/L
Conc. based on:
test mat.
Loading of aqueous phase:
0.5 g/L
Incubation duration:
ca. 20 min
Temp.:
24 °C
pH:
> 7
Remarks on result:
completely miscible

Applicant's summary and conclusion