Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2018
Report Date:
2018

Materials and methods

Test guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Other quality assurance:
other: ISO9001-2008
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
700 cps

Test material

Reference
Name:
Unnamed
Type:
Constituent
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Flash point:
ca. 98 °C
Atm. press.:
ca. 760 mm Hg

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met