Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2016
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN no. ST/SG/AC.10/11/Rev.6 Paragraph 32.4.1: Non-Viscous Flammable Liquids
Version / remarks:
2015
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM D7094. Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester
Version / remarks:
2012
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
other: Eraflash flash-point tester
Dynamic viscosity of test material:
27 - 63 mPa s at 23 °C (ISO 3219)
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: PX708164
- Expiration date of the lot/batch: 31 March 2018

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: At room temperature container flushed with nitrogen
Key result
Flash point:
30 °C
Atm. press.:
1 019 hPa

 Preliminary Test

The estimated flash-point of the test item was 32°C.

Main Study

The results of the main study on the determination of the flash-point of the test item are given in Table 7.


Table 7 Main Study: Flash-point of the Test Item

Test

Flash-point

[°C]

Lowest flash-point

[°C]

1

30

30

2

30

 

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash-point of the test item was 30°C
Executive summary:

The closed cup method was applied for the determination of the flash-point of Setalux 7002 BX-55.

The flash-point of the test item was 30°C.

Description of key information

The closed cup method was applied for the determination of the flash-point of Setalux 7002 BX-55. The flash-point of the test item is 30°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
30 °C

Additional information