Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
15 Feb 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
1992
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
Product Name: n-Hexyl Acrylate (HexA)
Batch Number: KAL1908
Appearance: Colourless liquid
Purity (GC): 98.52%
Storage Conditions: Ambient temperature in darkness
Retest After/Expiration Date: Not provided
Key result
Flash point:
71.5 °C
Atm. press.:
101.325 kPa

See attached tables for individual replicate observed and corrected values

Interpretation of results:
GHS criteria not met
Conclusions:
The mean measured observed flashpoint of the test substance was determined to be 71.5°C or 344.6K when corrected to one atmosphere pressure (101.325 kPa).

Description of key information

The mean measured observed flashpoint of the test substance was determined to be 71.5°C or 344.6K when corrected to one atmosphere pressure (101.325 kPa) by the EC A.9 method.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
71.5 °C

Additional information