Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 January 2018 - 16 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
Acetic acid, esters with lanolin alcs.
EC Number:
262-980-8
EC Name:
Acetic acid, esters with lanolin alcs.
Cas Number:
61788-49-6
Molecular formula:
C29H48O2
IUPAC Name:
Acetic acid, esters with lanolin alcs.
Test material form:
liquid

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: The substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 4 minutes test period (According to the EC A.10 guideline)

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Based on the results obtained, the test item is considered ‘not highly flammable’.
Executive summary:

The preliminary screening test was performed for the determination of the flammability of the test item. The test item was smeared into a column shape onto a non-combustible and non-porous plate. The test item column was 250 mm long with a width of 10 mm. A flame of a gas burner was applied to one end of the test item pile for 2 minutes.  The pile was visually interpreted for propagation of combustion either by burning with a flame or smouldering.  If applicable, the time of burning over a distance of 200 mm was measured after the pile had burned a distance of 50 mm. In contact with the flame of the gas burner the test item melted and turned into a yellow residue.  White smoke was observed.  After removal of the ignition source, no propagation of combustion of the test item was observed. No propagation of combustion of the test item along 200 mm length of the pile within 4 minutes was observed.  According to the guidelines, performance of the burning rate test is not required.  Based on the results obtained, the test item is considered ‘not highly flammable’.