Study period:
13 Oct 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2015
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Reference substance name:
9-Octadecenoic acid (Z)-, ester with oxybis[propanediol] (2:3)
EC Number:
289-147-1
EC Name:
9-Octadecenoic acid (Z)-, ester with oxybis[propanediol] (2:3)
Cas Number:
86088-80-4
Molecular formula:
not applicable, the substance is UVCB
IUPAC Name:
9-Octadecenoic acid (Z)-, ester with oxybis[propanediol] (2:3)

Results and discussion

Flash point
Flash point:
> 300 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: No flash point at up to testing instrument upper limit temperature (300 °C).

Any other information on results incl. tables

Test condition

Temperature: 21 °C; Humidity: 60 %RH; Atmospheric pressure: 1013 hPa

Test quantity

4 mL

Heating time

2 min

Flash point by seta-flash closed-cup

Test number

1

Above 300 °C *

2

Above 300 °C *

Average

Above 300 °C

Correction of observed flash point by atmospheric pressure

- °C

*No flash point at 300 °C (Testing instrument upper limit temperature: 300 °C)

Applicant's summary and conclusion