Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
142.5 °C
Atm. press.:
100.5 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point is 142.5 °C
Executive summary:

The flash point of the test item "sandalwood oil" has been tested according to the test method ASTM D93.

The flash point is 142.5 °C.

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
106 °C
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point = 106 °C

Description of key information

The flash point of the test item "sandalwood oil" has been tested according to the test method ASTM D93.

Two studies are available.

The flash point is 142.5 °C accoridng to the key study and 106 °C according to supporting study. As both values are above the GHS threshold for classification, the value of the key study is sued as the composition of this material is known in detail and the study was documented more properly.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
142.5 °C

Additional information