Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-04-27 to 2012-05-09
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report Date:
2012

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
1610 mPa*s a 20 °C, calculation based on density (1.154 g/cm³) and kinematic viscosity (1390 mm²/s)

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
183.5 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

Result

Predetermination: 180.0 °C

Measurement: corrected single value: 183.4 °C

This results in a flash point, corrected to normal pressure and rounded to 0.5 ° C, of: 183.5 °C

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met