Registration Dossier

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
explosive properties of explosives
Remarks:
Explosion protection systems -- Part 1: Determination of explosion indices of combustible dusts in air
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
ISO (the International Organization for Standardization) assay
Reference:
Composition 0
Qualifier:
according to
Guideline:
other: ISO 6184-1
Version / remarks:
Explosion protection systems -- Part 1: Determination of explosion indices of combustible dusts in air
Deviations:
no
GLP compliance:
not specified
Test material information:
Composition 1
Key result
Test series:
other: ISO 6184-1
Method:
other: Explosion protection systems — Part 1: Determination of explosion indices of combustible dusts in air
Parameter:
other: explosion index class
Remarks:
1 to 200 bar.m/s
Value:
1
Result:
negative, no violent effect on heating under confinement
Remarks on result:
no mass explosion
Interpretation of results:
GHS criteria not met
Conclusions:
Explosion index is low (class 1) on ISO 6184-1 assay - Explosion protection systems — Part 1: Determination of explosion indices of combustible dusts in air
Executive summary:

Explosion index is low (class 1) on ISO 6184-1 assay - Explosion protection systems — Part 1: Determination of explosion indices of combustible dusts in air

Endpoint:
explosiveness, other
Remarks:
Determination of the lower explosion limit LEL of dust clouds
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Reference:
Composition 0
Qualifier:
according to
Guideline:
other: EN 14034-3 (2006)
Version / remarks:
Determination Of Explosion Characteristics Of Dust Clouds - Part 3: Determination Of The Lower Explosion Limit Lel Of Dust Clouds
GLP compliance:
yes (incl. certificate)
Test material information:
Composition 1
Specific details on test material used for the study:
Sponsor sample identification : "Ultra - fines Erythritol" / Ineris sample identifiction : 07AA261
Sample received from the Sponsor on 03/01/07
Key result
Test series:
other: EN 14034-3
Method:
other: Determination Of Explosion Characteristics Of Dust Clouds
Parameter:
other: LIE = Limite inférieur d'explosivité
Remarks:
g/m3
Value:
30
Result:
negative, no ability to deflagrate
Remarks on result:
no mass explosion
Interpretation of results:
GHS criteria not met
Conclusions:
In an EN 14034-3 assay (Determination of explosion characteristics of dust clouds - Part 3: Determination of the lower explosion limit LEL of dust clouds), substance LEL is 30 g/m3
Executive summary:

In an EN 14034-3 assay (Determination of explosion characteristics of dust clouds - Part 3: Determination of the lower explosion limit LEL of dust clouds), substance LEL is 30 g/m3

Description of key information

Key value for chemical safety assessment

Explosiveness:
non explosive

Additional information

Justification for classification or non-classification