Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 26, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
not specified
Specific details on test material used for the study:
CAS No.: 544-31-0; EC No.: 208-867-9; Appearance: white solid at ambient temperature
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
other: CLP
Remarks:
not classified based on CLP
Conclusions:
Under the study conditions, the test substance has to be considered as non-flammable.
Executive summary:

A study was conducted to determine the flammability of the test substance according to EU Method A.10. Under the study conditions, the test substance has to be considered as non-flammable (Kintrup, 2017).

Description of key information

The flammability was determined according to EU Method A.10 (Kintrup, 2017).

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification