Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12.09.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
GLP compliance:
yes (incl. QA statement)
Remarks:
consilab, Gesellschaft für Anlagensicherheit mbH, Industriepark Höchst, G830/G840, 65926 Frankfurt am Main (Germany)

Test material

Constituent 1
Chemical structure
Reference substance name:
L-Alanine, N-coco acyl derivs., sodium salts
EC Number:
290-478-9
EC Name:
L-Alanine, N-coco acyl derivs., sodium salts
Cas Number:
90170-45-9
Molecular formula:
RHNNaO3
IUPAC Name:
L-Alanine, N-coco acyl derivs., sodium salts
Test material form:
solid
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Ajinomoto Co., Inc., 15-1, Kyobashi 1-chome, Chuo-ku, Tokyo 104-8315, Japan, Batch No.: 160325
- Expiration date of the lot/batch: 2020-03-25
- Purity test date: 2016-06-09

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: stored at ambient temperature

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
not classified based on GHS criteria
Conclusions:
In the preliminary test, the test item could not be ignited by a flame and therefore the performance of the main test was not necessary. Based on the result, the test item has not to be classified as readily combustible solid according to UN Transport Regulation nor as flammable solid according to CLP Regulation EC 1272/2008.
Executive summary:

The flammability of the test item was investigated in a study conducted according to UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids). In the preliminary test, the test item could not be ignited by a flame. Thus, the performance of the main test was not necessary. Based on the result, the test item has not to be classified as readily combustible solid according to UN Transport Regulation nor as flammable solid according to CLP Regulation EC 1272/2008.