Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From February 1, 2018 to March 14, 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

In preliminary screening test, I850 did not ignite for a maximum 2 minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
According to UN Manual of Tests and Criteria: Test N.1 test method, I850 is not classified as flammable solids. Therefore, I850 was not met GHS criteria.
Executive summary:

The flammability properties of I850 was determined according to UN Manual of Tests and Criteria: Test N.1. In preliminary screening test, the test result showed that I850 did not ignite for a maximum 2 minutes. Therefore, I850 is not a flammable solids.

Description of key information

I850 is not classified as flammable solids (UN Manual of Tests and Criteria: Test N.1)

Key value for chemical safety assessment

Flammability:
not classified

Additional information

In preliminary screening test, the test result showed that I850 did not ignite for a maximum 2 minutes. Therefore, I850 is not a flammable solids.

Justification for classification or non-classification