Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
Study conducted following ASTM D56-15 -Procedure A
Qualifier:
according to guideline
Guideline:
ASTM D56 (Standard test method for flash point by tag closed cup tester)
Version / remarks:
Procedure A
Deviations:
no
GLP compliance:
no
Remarks:
conducted under good manufacturing practices (GMP)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Remarks on result:
no flash point up to 100°C
Remarks:
No flash observed. Flame extinguished at 219 F
Interpretation of results:
study cannot be used for classification
Conclusions:
Not able to determined flash point using ASTM D56 Procedure A. No flash point up to 100°C. Flame extinguished at 219°F and no flash was observed.

Description of key information

Not able to determine flash point using ASTM D56 Procedure A. No flash point up to 100°C. Flame extinguished at 219°F and no flash was observed.

Key value for chemical safety assessment

Additional information