Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 225-803-5 | CAS number: 5089-22-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- water solubility
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- January from 14 to 25, 2019
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with generally accepted scientific standards and described in sufficient detail
- Reason / purpose for cross-reference:
- reference to other study
- Remarks:
- validated analytical method
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 105 (Water Solubility)
- Version / remarks:
- adopted July 27, 1995
- Deviations:
- yes
- Remarks:
- the means obtained from two tests with different flows differ by more than 30 %;anyway, the deviation is not considered to affect the integrity and validity of the Study.
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.6 (Water Solubility)
- Version / remarks:
- 19 March 2014
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7840 (Water Solubility)
- Version / remarks:
- March 1998
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- column elution method
- Water solubility:
- 0.002 mg/L
- Conc. based on:
- test mat.
- Temp.:
- 20 °C
- pH:
- 7.4 - 8.4
- Details on results:
- The mean concentration at 25 ml/hour flow rate resulted to be 0.00108 µg/ml and the mean concentration at 12.5 ml/hour flow rate resulted to be 0.00136 µg/ml.
Before the pH measurement, 2-point calibration of the pH meter was performed. The calibrated range was between 7.000 and 10.000, the measurement was performed at 20 ±1 °C. The measured pH values were between 7.4 and 8.4.
The means obtained from two tests with different flows differ by more than 30 %; this deviation from testing guideline is considered to be due to limitations of the analytical method at very low concentration. Anyway, the deviation is not considered to affect the integrity and validity of the Study.
CALIBRATION
Mean of the peak areas versus the concentration of the test item showed good linearity in the whole tested range of 0.0001 – 0.1 µg/ml. The calibration graph was calculated applying weighted linear regression. The weighting factor was 1/concentration. - Conclusions:
- Water solubility: 0.0015 mg/l at 20 °C and pH 7.4 -8.4
- Executive summary:
The water solubility of the test item was determined using the column elution method, according to the OECD guideline 105.
A preliminary test for solubility was carried out as a range finding test for the decision whether the column elution method or the flask method needed to be used for the performance of the main test: a saturated solution of the test item in water was prepared by shaking a mixture of the test item and water at room temperature; after filtration the concentration of the saturated solution was determined to be less than 10 mg/l, therefore the column elution method was chosen for the main test.
Approximately 25 mg of the test item was dissolved in 25 ml tetrahydrofuran and this solution was added to 100 g of the support material. The solvent was completely evaporated. The dry, loaded support material was poured into the micro-columns. They were filled with water and the system was then equilibrated for two hours.
Then the columns were connected to the re-circulating pump. The columns were maintained at 20 ± 0.5 °C. Two different flow rates were applied: 25 ml/hour and 12.5 ml/hour with two replicate micro-columns.
During the calibration, mean of the peak areas versus the concentration of the test item showed good linearity in the whole tested range of 0.0001 – 0.1 µg/ml.
The mean concentration at 25 ml/hour flow rate resulted to be 0.00108 µg/ml and the mean concentration at 12.5 ml/hour flow rate resulted to be 0.00136 µg/ml; therefore the solubility resulted to be 0.0015 µg/ml at 20 °C; the measured pH values were between 7.4 and 8.4.
The means obtained from two tests with different flows differ by more than 30 %; this deviation from testing guideline is considered to be due to limitations of the analytical method at very low concentration. Anyway, the deviation is not considered to affect the integrity and validity of the Study.
Conclusion
Water solubility: 0.0015 mg/l at 20 °C and pH 7.4 -8.4
Reference
Measured concentration of test item
Time Period | Mean concentration, µg/ml Column 1. |
Mean concentration, µg/ml Column 2. |
Measured concentration of test item at 25 ml/hour flow rate |
||
70 hours | 0.00137 | 0.00107 |
71 hours | 0.00114 | 0.00086 |
72 hours | 0.00114 | 0.00110 |
73 hours | 0.00114 | 0.00104 |
74 hours | 0.00103 | 0.000916 |
Mean | 0.00117 µg/ml | 0.000997 µg/ml |
RSD | 11 % | 11 % |
Mean all | 0.00108 µg/ml | |
Measured concentration of test item at 12.5 ml/hour flow rate |
||
120 hours | 0.000170 | 0.000116 |
121 hours | 0.000108 | 0.000088 |
122 hours | 0.000103 | 0.000145 |
123 hours | 0.000142 | 0.000147 |
124 hours | 0.000185 | 0.000159 |
Mean | 0.000142 µg/ml | 0.000131 µg/ml |
RSD | 26 % | 22 % |
Mean all | 0.000136 µg/ml |
Description of key information
0.0015 mg/l at 20 °C and pH 7.4 -8.4
Key value for chemical safety assessment
- Water solubility:
- 0.002 mg/L
- at the temperature of:
- 20 °C
Additional information
OECD 105 - column elution method
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.