Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
other: DIN 66165
Principles of method if other than guideline:
The particle size distribution was determined according to DIN 66165: "Particle size analysis - Sieving analysis ".
GLP compliance:
no
Type of method:
sieving
No.:
#1
Size:
> 1 400 µm
Distribution:
0 %
No.:
#1
Size:
> 1 000 - < 1 400 µm
Distribution:
0.1 %
No.:
#1
Size:
> 800 - < 1 000 µm
Distribution:
1.2 %
No.:
#1
Size:
> 500 - < 800 µm
Distribution:
28.8 %
No.:
#1
Size:
> 400 - < 500 µm
Distribution:
24.4 %
No.:
#1
Size:
> 300 - < 400 µm
Distribution:
24.9 %
No.:
#1
Size:
> 200 - < 300 µm
Distribution:
14.3 %
No.:
#1
Size:
> 100 - < 200 µm
Distribution:
5.6 %
No.:
#1
Size:
> 50 - < 100 µm
Distribution:
0.7 %
No.:
#1
Size:
< 50 µm
Distribution:
0 %

Description of key information

The particle size distribution was determined according to DIN 66165: "Particle size analysis - Sieving analysis ":

Size of the sieve

%

>1.4 mm

0.0

>1 mm

0.1

>800 µm

1.2

>500 µm

28.8

>400 µm

24.4

>300 µm

24.9

>200 µm

14.3

>100 µm

5.6

>50 µm

0.7

<50 µm

0

Additional information