Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Particle size distribution (Granulometry)
Administrative data
- Endpoint:
- particle size distribution (granulometry)
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 08 January 2009 to 26 February 2009
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 009
- Report date:
- 2009
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Date of inspection: 19 August 2008; Date of signature: 04 March 2009
- Type of method:
- determination of fibre length and diameter distributions
- Type of distribution:
- volumetric distribution
Test material
Results and discussion
Particle size
- Percentile:
- D50
- Remarks on result:
- other: Too few particles were of a size less than 10.0 µm to allow accurate assessment of mass median aerodynamic diameter.(migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.)
Particle size distribution at different passagesopen allclose all
- No.:
- #1
- Size:
- > 100 µm
- Distribution:
- 34.8 %
- Remarks on result:
- other: Proportion of test material having an inhalable particle size less than 100 µm using the sieve method.
- No.:
- #2
- Size:
- > 10 µm
- Distribution:
- <= 0.431 %
- Remarks on result:
- other: Proportion of test material having a thoracic particle size less than 10.0 µm using the Cascade Impactor method.
- No.:
- #3
- Size:
- > 5.5 µm
- Distribution:
- <= 0.16 %
- Remarks on result:
- other: Proportion of test material having a respirable particle size less than 5.5 µm using the Cascade Impactor method
Any other information on results incl. tables
Screening test (sieve method)
The results of the sieving procedure are shown in the following table:
Table 2
Sieve aperture size (µm) |
100 |
Mass of test material transferred to sieve (g) |
10.07 |
Mass of test material passed through sieve (g) |
3.50 |
Test material less than sieve aperture size (%) |
34.8 |
Definitive test (cascade impactor method)
Determination 1
The results of the cascade impactor method are shown in the following table:
Table 3 Determination 1
Cup Number |
ParticleCollected (µm) |
Cup Masses (g) |
||
Pre-sampling |
Post-sampling |
Difference |
||
1 |
>10.0 |
86.1243 |
88.9262 |
2.8019 |
2 |
5.5 - 10.0 |
85.3993 |
85.4076 |
0.0083 |
3 |
2.4 - 5.5 |
85.9171 |
85.9192 |
0.0021 |
4 |
1.61 - 2.4 |
85.6346 |
85.6355 |
0.0009 |
5 |
0.307 - 1.61 |
85.7978 |
85.7996 |
0.0018 |
Filter |
<0.307 |
0.1223 |
0.1224 |
0.0001 |
Amount of test material found in
artificial throat: 0.25 g.
Total amount of test material recovered from impactor cups, filter and
artificial throat: 3.07 g.
The cumulative amounts found for the individual particle size cut-points (µm) are shown in the following table:
Table 4 Determination 1
Cup Number |
Particle Size Cut-points (µm) |
Cumulative Mass of Test Material (g) |
Cumulative Amount of Test Material (%) |
2 |
10.0 |
0.0132 |
0.431 |
3 |
5.5 |
0.0049 |
0.160 |
4 |
2.4 |
0.0028 |
9.14 x 10-2 |
5 |
1.61 |
0.0019 |
6.20 x 10-2 |
Filter |
0.307 |
0.0001 |
3.26 x 10-3 |
Determination 2
The results of the cascade impactor method are shown in the following table:
Table 5 Determination 2
Cup Number |
ParticleCollected (µm) |
Cup Masses (g) |
||
Pre-sampling |
Post-sampling |
Difference |
||
1 |
>10.0 |
86.1248 |
89.0369 |
2.9121 |
2 |
5.5 - 10.0 |
85.4004 |
85.4074 |
0.0070 |
3 |
2.4 - 5.5 |
85.9194 |
85.9195 |
0.0001 |
4 |
1.61 - 2.4 |
85.6385 |
85.6394 |
0.0009 |
5 |
0.307 - 1.61 |
85.8027 |
85.8029 |
0.0002 |
Filter |
<0.307 |
0.1179 |
0.1179 |
0 |
Amount of test material found in
artificial throat: 0.08 g.
Total amount of test material recovered from impactor cups, filter and
artificial throat: 3.00 g.
The cumulative amounts found for the individual particle size cut-points (µm) are shown in the following table:
Table 6 Determination 2
Cup Number |
Particle Size Cut-points (µm) |
Cumulative Mass of Test Material (g) |
Cumulative Amount of Test Material (%) |
2 |
10.0 |
0.0082 |
0.273 |
3 |
5.5 |
0.0012 |
4.00 x 10-2 |
4 |
2.4 |
0.0011 |
3.67 x 10-2 |
5 |
1.61 |
0.0002 |
6.67 x 10-3 |
Filter |
0.307 |
0 |
0 |
Determination 3
The results of the cascade impactor method are shown in the following table:
Table 7 Determination 3
Cup Number |
ParticleCollected (µm) |
Cup Masses (g) |
||
Pre-sampling |
Post-sampling |
Difference |
||
1 |
>10.0 |
86.1232 |
89.0183 |
2.8951 |
2 |
5.5 - 10.0 |
85.3995 |
85.4062 |
0.0067 |
3 |
2.4 - 5.5 |
85.9185 |
85.9189 |
0.0004 |
4 |
1.61 - 2.4 |
85.6349 |
85.6353 |
0.0004 |
5 |
0.307 - 1.61 |
85.7991 |
85.7994 |
0.0003 |
Filter |
<0.307 |
0.1177 |
0.1177 |
0 |
Amount of test material found in
artificial throat: 0.13 g.
Total amount of test material recovered from impactor cups, filter and
artificial throat: 3.03 g.
The cumulative amounts found for the individual particle size cut-points (µm) are shown in the following table:
Table 8 Determination 3
Cup Number |
Particle Size Cut-points (µm) |
Cumulative Mass of Test Material (g) |
Cumulative Amount of Test Material (%) |
2 |
10.0 |
0.0078 |
0.257 |
3 |
5.5 |
0.0011 |
3.63 x 10-2 |
4 |
2.4 |
0.0007 |
2.31 x 10-2 |
5 |
1.61 |
0.0003 |
9.89 x 10-3 |
Filter |
0.307 |
0 |
0 |
The overall cumulative amounts of test material with a particle size less than 10.0 µm (%) from Determinations 1 to 3 are shown in the following table:
Table 9
Determination |
Cumulative Amount of Test Material Less Than 10.0 µm (%) |
Mean Cumulative Amount of Test Material Less Than 10.0 µm (%) |
1 |
0.431 |
≤0.431 |
2 |
0.273 |
|
3 |
0.257 |
The overall cumulative amounts of test material with a particle size less than 5.5 µm (%) from Determinations 1 to 3 are shown in the following table:
Table 10
Determination |
Cumulative Amount of Test Material Less Than 5.5 µm (%) |
Mean Cumulative Amount of Test Material Less Than 5.5 µm (%) |
1 |
0.160 |
≤0.160 |
2 |
4.00 x 10-2 |
|
3 |
3.63 x 10-2 |
Applicant's summary and conclusion
- Conclusions:
- Particle size data acquired for the test material are shown in the table below.
- Executive summary:
Particle size data have been acquired using a procedure designed to comply with the European Commission technical guidance document 'Particle Size Distribution, Fibre Length and Diameter Distribution' (June 1996), which satisfies the requirents of OECD Guideline 110.
The results are as follows:
Measurent
Method
Result
Proportion of test material having an inhalable particle size less than 100 µm
Sieve
34.8%
Proportion of test material having a thoracic particle size less than 10.0 µm
Cascade Impactor
≤0.431%
Proportion of test material having a respirable particle size less than 5.5 µm
Cascade Impactor
≤0.160%
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.