Registration Dossier

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures

General information:

- Immediately remove any clothing soiled by the product.

- Involve doctor immediately.

After inhalation:

- In case of unconsciousness place patient stably in side position for transportation.

- Supply fresh air; consult doctor in case of complaints.

After skin contact:

- Immediately wash with water and soap and rinse thoroughly.

- Avoid contact with UV- and sunlight.

After eye contact:

- Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

After swallowing:

- Call a doctor immediately.

- Rinse out mouth and then drink plenty of water.

Most important symptoms and effects, both acute and delayed

- No further relevant information available.

Indication of any immediate medical attention and special treatment needed

- No further relevant information available.

Fire-fighting measures

Extinguishing media

Suitable extinguishing agents:

- CO2, powder or water spray.

- Fight larger fires with water spray or alcohol resistant foam.

- Use fire extinguishing methods suitable to surrounding conditions.

For safety reasons unsuitable extinguishing agents:

- Water with full jet.

Special hazards arising from the substance or mixture

In case of fire, the following can be released:

- COx

Advice for firefighters

Protective equipment:

- Wear self-contained respiratory protective device.

- Wear fully protective suit.

Accidental release measures

Personal precautions, protective equipment and emergency procedures

- Ensure adequate ventilation.

- Keep people at a distance and stay on the windward side.

Environmental precautions

- Inform respective authorities in case of seepage into water course or sewage system.

- Do not allow to enter sewers/ surface or ground water.

Methods and material for containment and cleaning up

- Pick up mechanically.

Reference to other sections

- See Section Handling and storage for information on safe handling.

- See Section Exposure controls/personal protection for information on personal protection equipment.

- See Section Disposal considerations for disposal information.

Handling and storage

Precautions for safe handling

- Ensure good ventilation/exhaustion at the workplace.

- Open and handle receptacle with care.

Information about fire - and explosion protection:

- Keep ignition sources away - Do not smoke.

- Protect from heat.

Conditions for safe storage, including any incompatibilities

Storage:

Requirements to be met by storerooms and receptacles:

- No special requirements.

Information about storage in one common storage facility:

- Not required.

Further information about storage conditions:

- Keep container tightly sealed.

- Store in cool, dry conditions in well-sealed receptacles.

- Protect from heat and direct sunlight.

- Store receptacle in a well ventilated area.

- Store under lock and key or with access restricted to technical experts or their assistants only.

- Do not expose to temperatures above 40 °C.

Specific end use(s)

- No further relevant information available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Void
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Void
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Void
Shipping information
Proper shipping name and description:
Void
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Void
Shipping information
Proper shipping name and description:
Void
Remarksopen allclose all

Additional transport information

Additional information
Special provisions / remarks / other:
Special precautions for user:
Not applicable

Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code:
Not applicable

Exposure controls / personal protection

Additional information about design of technical facilities:

- No further data; see item Handling and storage.

Control parameters

Ingredients with limit values that require monitoring at the workplace:

- The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace.

Additional information:

- The lists valid during the making were used as basis.

Exposure controls

Personal protective equipment:

General protective and hygienic measures:

- The usual precautionary measures are to be adhered to when handling chemicals.

- Keep away from foodstuffs, beverages and feed.

- Immediately remove all soiled and contaminated clothing.

- Wash hands before breaks and at the end of work.

- Avoid contact with the eyes and skin.

Respiratory protection:

- Respirator must be worn if exposed to dust.

Protection of hands:

- Protective gloves.

Material of gloves:

- Products without solvents added: wear nitrile gloves.

- Replace gloves immediately when torn or any change in appearance (dimension, colour, flexibility etc.) is noticed.

Penetration time of glove material:

- The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye protection:

- Tightly sealed goggles.

- Goggles recommended during refilling.

Body protection:

- Impervious protective clothing.

Stability and reactivity

Reactivity

Chemical stability

Thermal decomposition / conditions to be avoided:

- No decomposition if used and stored according to specifications.

Possibility of hazardous reactions

- No dangerous reactions known.

Conditions to avoid

- No further relevant information available.

Incompatible materials

- Incompatible with acids and bases.

- Avoid moisture.

Hazardous decomposition products

- No dangerous decomposition products known.

Disposal considerations

Waste treatment methods

Recommendation:

- Can be incinerated, when in compliance with local regulations.

European waste catalogue:

- 16 03 05: organic wastes containing dangerous substances.

Uncleaned packaging

Recommendation:

- Disposal must be made according to official regulations.

- Packaging may be reused or recycled after cleaning.