Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reference:
Composition 1
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: Normalab NPV310, Inv. No. 49405775
Test material information:
Composition 1
Remarks on result:
no flash point - measurement carried out until boiling temperature
Remarks:
No flashpoint was observed up to 103°C, afterwards boiling was observed.

Table 1: Preliminary test

Test item / mL

Starting temperature / °C

Heating / °C/min

Final temperature / °C

Ignition + / -

2

10

5

100

-

4

100

5

103

-

4

100

5

103

-

Interpretation of results:
GHS criteria not met
Conclusions:
No flashpoint was observed for tetraamminepalladium dihydroxide up to 103°C, afterwards boiling was observed.
Executive summary:

Nau (2017) is a GLP-compliant study following EU method A9. It is considered suitable for use as the key study for this endpoint. No flashpoint was observed for tetraamminepalladium dihydroxide up to 103°C, afterwards boiling was observed.

Description of key information

No flashpoint was observed for tetraamminepalladium dihydroxide up to 103°C, afterwards boiling was observed.

Key value for chemical safety assessment

Additional information

Nau (2017) is a GLP-compliant study following EU method A9. It is considered suitable for use as the key study for this endpoint. No flashpoint was observed for tetraamminepalladium dihydroxide up to 103°C, afterwards boiling was observed.