Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4 October 2010 to 13 December 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP compliant, guideline study, available as unpublished report, acceptable without restrictions
Qualifier:
equivalent or similar to
Guideline:
other: N4 (Modified Method) Self Heating Substances
Deviations:
yes
Remarks:
the test item was only available in very limited amounts and was extremely expensive. therefore, in order to obtain as much information as possible on the self heating properties of the test item a modified procedure was employed
GLP compliance:
yes (incl. certificate)
Remarks on result:
other: No signs of self-ignition or self heating at 140 °C, however the test item exceeded the oven temperature by approximately 70 °C at an oven temperature of approximately 310 °C

Tetraamminepalladium(2+) dichloride showed no signs of self-ignition or self heating at 140 °C, however the test item exceeded the oven temperature by approximately 70 °C at an oven temperature of approximately 310 °C

Conclusions:
Tetraamminepalladium(2+) dichloride showed no signs of self-ignition or self heating at 140 °C, however the test item exceeded the oven temperature by approximately 70 °C at an oven temperature of approximately 310 °C
Executive summary:

This is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint. Tetraamminepalladium(2+) dichloride showed no signs of self-ignition or self heating at 140°C, however the test item exceeded the oven temperature by approximately 70 °C at an oven temperature of approximately 310 °C.

Description of key information

Tetraamminepalladium(2+) dichloride showed no signs of self-ignition or self-heating at 140°C, however the test item exceeded the oven temperature by approximately 70°C at an oven temperature of approximately 310°C.

Key value for chemical safety assessment

Additional information

Atwal and Tremain (2011) is a GLP compliant, guideline study considered suitable for use as the key study for this endpoint.Tetraamminepalladium(2+) dichloride showed no signs of self-ignition or self-heating at 140°C, however the test item exceeded the oven temperature by approximately 70°C at an oven temperature of approximately 310°C.