Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
December 09, 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: ASTM E 794-95
GLP compliance:
yes
Type of method:
differential scanning calorimetry
Melting / freezing pt.:
ca. 267.82 °C
Decomposition:
no
Sublimation:
no
Remarks on result:
other: average value

The results for the melting tests, carried out in duplicate on three samples of different lots, are shown below. At the end of each analysis, the corresponding thermic curves were recorded. Each curve reported the heat flow, on the ordinate, as a function of temperature, on the abscissa. For each analysis, the values of the melting temperature, corresponding to the temperature at which the peak of the thermogram reaches the maximum, was determined. For each analysis, the values of the ONSET and ENDSET temperature, at which the melting process begins and ends, respectively, were also determined.

Determination of the melting temperature

 

 

mass (mg)

Tonset(ºC)

Tendset(ºC)

Tpeak(ºC)

Sample I

(lot 5169)

Test 1

2,59

265,28

271,27

267,98

Test 2

3,50

265,01

271,36

268,09

Sample II

(lot 5181)

Test 3

3,48

264,97

272,09

267,65

Test 4

3,30

264,55

272,40

267,84

Sample III

(lot 5280)

Test 5

3,44

264,88

272,00

267,62

Test 6

3,17

264,52

272,18

267,79

The Table shows the results obtained from the test for the determination of the melting temperature of the test substance. From tests carried out in duplicate on three samples of different lots, Sample I returned an average value of the melting temperature equal to 268,03 ºC. Sample II returned an average value of the melting temperature equal to 267,74 ºC. Sample III returned an average value of the melting temperature equal to 267,70 ºC.

Conclusions:
The value of the melting temperature corresponding to the fusion of the test substance, obtained from the average of the values returned from each test, resulted equal to 267.82 ºC.
Executive summary:

Method

The test item melting point was determined using the Differential Scanning Calorimetry (DSC) according to the ASTM E 794 -95.

Discussion

Following the operative conditions described in the method, tests carried out in duplicate on a same sample, by the same operator, in the same laboratory, with the same apparatus and in a brief range of time, should not differ more than ± 0.2 °C at a probability level of 95 %. The values of the melting temperature corresponding to the fusion of the test substance, obtained from the tests performed in duplicate on a same sample do not differ more than 0.19 °C. The tests performed have therefore a precision lower than the limit imposed by the method and they can be considered valid.

Results

The value of the melting temperature corresponding to the fusion of the test substance, obtained from the average of the values returned from each test, resulted equal to 267.82 °C.

Description of key information

Melting point = 267.82 °C

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
267.82 °C

Additional information

The test item melting point was determined using the Differential Scanning Calorimetry (DSC) according to the ASTM E 794 -95.