Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Well documented but not according to GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Principles of method if other than guideline:
The equipment has been calibrated with distilled water (d 20°C = 0.99821 g/cm3) and 2,4 dichlorotoluene (d20°C = 1.24931 g/cm3).

Five replicates have been performed.
GLP compliance:
no
Type of method:
oscillating densitimeter

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of disodium carbonate and disodium sulfate and sodium chloride
EC Number:
908-570-0
Molecular formula:
not applicable - multi-constituent substance
IUPAC Name:
Reaction mass of disodium carbonate and disodium sulfate and sodium chloride

Results and discussion

Density
Key result
Type:
relative density
Density:
ca. 1.186 g/cm³
Temp.:
20 °C

Any other information on results incl. tables

The individual values, mean value and standard deviation are presented below.

 

Trial

Relative density

1

1.18625

2

1.18623

3

1.18622

4

1.18628

5

1.18625

Mean Value

1.18625

Standard deviation

0.00002


 