Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: DIN 66165 ISO 3310
GLP compliance:
yes (incl. QA statement)
Type of distribution:
mass based distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
Carbamic acid, N-[3-(tiethoxysilyl) propyl]-, 2-[ethyl(4-nitrosophenyl)amino]ethyl ester
Cas Number:
1195231-94-7
Molecular formula:
C20 H35 N3 O6 Si
IUPAC Name:
Carbamic acid, N-[3-(tiethoxysilyl) propyl]-, 2-[ethyl(4-nitrosophenyl)amino]ethyl ester
Constituent 2
Reference substance name:
[SPEC][/SPEC][SYN][/SYN][AM][/AM]
IUPAC Name:
[SPEC][/SPEC][SYN][/SYN][AM][/AM]
Constituent 3
Reference substance name:
[CS]000000419807[/CS]
IUPAC Name:
[CS]000000419807[/CS]

Results and discussion

Mass median aerodynamic diameter:
2 851 µm
Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
346 µm
Remarks on result:
other: The determination of a standard deviation of the particle size distribution is not possible due the fact the maximum of the distribution is in the fraction above 1400 µm
Percentile:
D50
Mean:
2 851 µm
Remarks on result:
other: The determination of a standard deviation of the particle size distribution is not possible due the fact the maximum of the distribution is in the fraction above 1400 µm
Percentile:
D90
Mean:
5 370 µm
Remarks on result:
other: The determination of a standard deviation of the particle size distribution is not possible due the fact the maximum of the distribution is in the fraction above 1400 µm

Applicant's summary and conclusion

Conclusions:
The test item has a particle size of X10 = 346 µm; X50 = 2851 µm and X90 = 5370 µm. MMAD = 2851 µm