Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to
Guideline:
EU Method A.3 (Relative Density)
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
yes (incl. certificate)
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Density
Type:
relative density
Density:
1.186
Temp.:
20 °C

Applicant's summary and conclusion

Conclusions:
The relative Density of the test item was determined to D20 4 = 1.186