Registration Dossier

Diss Factsheets

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 26, 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: guideline study (EC A.2. and OECD 103)
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Boiling pt.:
> 500 °C
Atm. press.:
ca. 1 013 hPa
Decomposition:
yes
Decomp. temp.:
> 260 - < 440 °C

Results:

The measurements in aluminium crucibles with a hole showed no endothermal effect up to the decomposition of the test item. The test item had no boiling point at atmospheric conditions because it decomposed first.
Executive summary:
The test item had no boiling point at atmospheric conditions because it decomposed first.

Description of key information

The boiling point / boiling range of the test item was determined according to the European Commission Regulation (EC) No. 440/2008, Method A.2  and according to the OECD test guideline, OECD 103.

Key value for chemical safety assessment

Additional information

The test item had no boiling point at atmospheric conditions because it decomposed first.