Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
no
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

This substance did not ignite when contact with flame for two minutes.

This substance is not flammable under this test condition.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
This substance did not ignite when contact with flame for two minutes.
This substance is not flammable under this test condition.


Executive summary:

Preliminary test on the flammability for sodium p-styrenesulfone was evaluated according to EU method A.10 (solid).

This substance did not ignite when contact with flame for two minutes.

This substance is not flammable under this test condition.

Description of key information

Preliminary test on the flammability for sodium p-styrenesulfone was evaluated according to EU method A.10 (solid).

This substance did not ignite when contact with flame for two minutes.

This substance is not flammable under this test condition.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

The test substance does not meet the criteria for CLP, therefore, is Not Classified.