Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
June 27,2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Principles of method if other than guideline:
Laser light scattering. The particle size distribution was analysed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measure the size of particles. It does this by measuring the intensity of light scattered as a laser beam passes through a dispersed particulate sample. This data is then analysed to calculate the size of the particles that created the scattering pattern.Study conducted according to SOP - STR 071 method
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
ca. 5.824 µm
Remarks on result:
other: After 2 minutes of ultrasonic treatment
Percentile:
D50
Mean:
ca. 26.309 µm
Remarks on result:
other: After 2 minutes of ultrasonic treatment
Percentile:
D90
Mean:
ca. 76.845 µm
Remarks on result:
other: After 2 minutes of ultrasonic treatment

Particle size

Percentile

Mean

St. dev.

Remarks

D10

ca. 5.824 µm

 

 

D50

ca. 26.309 µm

 

 

D90

ca. 76.845 µm

 

 

Conclusions:
D10= ca. 5.824 µmD50= ca. 26.309 µmD90= ca. 76.845 µm
Executive summary:

Method

The particle size distribution was analyzed using the Mastersizer 2000 tool, which uses the technique of laser diffraction to measure the size of particles. It does this by measuring the intensity of light scattered as a laser beam passes through a dispersed particulate sample. This data is then analyzed to calculate the size of the particles that created the scattering pattern.

Result

D10= ca. 5.824 µm

D50= ca. 26.309 µm

D90= ca. 76.845 µm

Description of key information

MMD = 26.309 µm

Additional information

The analysis were performed according to the Laser Light Scattering method.

D10= ca. 5.824 µm

D50= ca. 26.309 µm

D90= ca. 76.845 µm