Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

No melting point could be determined at atmospheric pressure as the test substance decomposed first.

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
300 °C

Additional information

The melting point of the test substance was assessed following EC method A.1 (92/69/EEC) and OECD guideline 102 in compliance with GLP regulations. The differential scanning calorimetry (DSC: Mettler -Toledo TA8000) method was used, with a closed glass crucible. Under the test conditions, the test substance did not show any endothermic effect prior to the exothermal decomposition. The test substance has no melting point at atmospheric pressure as the test substance decomposes first.