Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: no GLP
Qualifier:
equivalent or similar to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point:
114 °C
Atm. press.:
1 atm
Conclusions:
The flashpoint for this substance is determined to be 114 °C.
Executive summary:

The flashpoint for this substance is determined by Pensky Martens Closed Cup method (ASTM-D93) to be 114 °C.

Description of key information

The flashpoint for this substance is determined by Pensky Martens Closed Cup method (ASTM-D93)  to be 114 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
114 °C

Additional information