Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
weight of evidence
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The tested samples were crushed prior to testing. Therefore the result of the test should be used with caution and hence the reliability code assigned.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
no guideline followed
Principles of method if other than guideline:
An ISO certified lab determinated the particle seize by seiving. The sieves used are classified ASTM’s sieves and the grain sizes are from 0,020mm to 3,36 mm.
GLP compliance:
no
Remarks:
other quality assurance
Type of distribution:
counted distribution

Test material

Constituent 1
Reference substance name:
Slimes and Sludges, battery scrap, antimony- and lead-rich
EC Number:
310-061-8
EC Name:
Slimes and Sludges, battery scrap, antimony- and lead-rich
Cas Number:
102110-60-1
Molecular formula:
Molecular weigth/formula concept not applicable to Inorganic UVCB (comlex metal containing substance)
IUPAC Name:
Slimes and Sludges, battery scrap, antimony- and lead-rich
Details on test material:
The samples were crushed prior to testing.

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D50
Mean:
< 20 µm
Remarks on result:
other: sample 10TT03302
Percentile:
other: D80
Mean:
33 µm
Remarks on result:
other: sample 10TT03302
Percentile:
D50
Mean:
39 µm
Remarks on result:
other: sample 10TT00905
Percentile:
other: D80
Mean:
64 µm
Remarks on result:
other: sample 10TT00905

Any other information on results incl. tables

Size

 

10TT03302

10TT00905

mesh

 mm

%

%

 

5

 

 

6

3.35

 

 

8

2.38

 

0.52

16

1.19

0.02

0.76

20

0.841

0.04

1.15

30

0.595

0.09

1.51

40

0.42

0.11

1.56

50

0.297

0.18

6.92

140

0.105

2.83

4.43

200

0.074

2.77

10.33

325

0.044

7.20

68.13

 

0.02

17.16

4.68

 

-0.02

69.60

0.52

Sum

 

100.00

100.00

Applicant's summary and conclusion

Conclusions: