Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The study was conducted according to EEC Test Method A15, Auto-ignition temperature with GLP compliance.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
(1E)-1,3-dichloroprop-1-ene; 1,2-dichloropropane
EC Number:
904-304-2
Molecular formula:
Multi-constituent: C3H4Cl2 and C3H6Cl2
IUPAC Name:
(1E)-1,3-dichloroprop-1-ene; 1,2-dichloropropane
Constituent 2
Reference substance name:
Reaction mass of 1,2-dichloropropane and 1,3-dichloropropene,
IUPAC Name:
Reaction mass of 1,2-dichloropropane and 1,3-dichloropropene,
Constituent 3
Reference substance name:
Crude 1,3-dichloropropene
IUPAC Name:
Crude 1,3-dichloropropene
Details on test material:
As per IUCLID5 Sections 1.1. - 1.4.

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
>= 400 °C
Atm. press.:
1 023 mBar
Remarks on result:
other:

Applicant's summary and conclusion

Conclusions:
Crude 1,3-dichloropropene was determined not to auto-ignite at up to 400°C over a volume range of 70 - 1000 uL.
Executive summary:

The Auto-flammability/ignition temperature of Crude 1,3 -dichloropropene was accessed by EEC Test Method A15 with GLP compliance. Crude 1,3-dichloropropene was determined not to auto-ignite at up to 400°C over a volume range of 70 - 1000 uL.