Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Endpoint summary

Administrative data

Description of key information

Additional information

Appearance:

Cesium iodide is a coulorless, odourless inorganic solid.

Melting point:

The melting point of cesium iodide was determined to be 628 °C at 1013.25 hPa.

Boiling point

In accordance with column 2 of REACH Regulation (EC) No 1907/2006 Annex VII section 7.3, the study does not need to be conducted for solids which either melt above 300 °C or decompose before boiling. The melting point of cesium iodide was determined to be 628 °C at 1013.25 hPa (see above or IUCLID Section 4.2: Key.001.Melting point.AQura GmbH.2010).

Density:

The density of cesium iodide was determined to be 4.51 g/cm³ at 20 °C.

Particle size distribution:

The averages of three measurements were as follows: d10: 125 µM, d50: 226 µM, d90: 391 µM.

Vapour pressure:

In accordance with column 2 of REACH Regulation (EC) No 1907/2006 Annex VII section 7.5, the vapour pressure does not need to be conducted if the melting point is above 300 °C. The melting point of cesium iodide was determined to be 628 °C at 1013.25 hPa (see above or IUCLID Section 4.2: Key.001.Melting point.AQura GmbH.2010).

Partion coefficient:

In accordance with column 2 of REACH Regulation (EC) No 1907/2006 Annex VII, the test on partition coefficient n-octanol/water (required in REACH Regulation, Annex VII, section 7.8) does not need to be conducted if the substance is inorganic. Cesium iodide is an inorganic compound. The log Kow of the cesium iodide was estimated to be 1.04. However, cesium iodide is an inorganic salt and the value calculated with the program KOWWIN should be considered with caution. Due to the salt character of cesium iodide and its good water solubility the log Pow is assumed to be 0.

Water solubility:

The water solubility of cesium iodide was determined to be 669.7 g/L at 20 °C. Therefore, the test item is very soluble.

Surface tension:

The surface tension of cesium iodide was determined to be 69.2 mN/m at 20 °C.

Flash point:

As cesium iodide is a solid at room temperature, the determination of the flash point is scientifically unjustified and therefore was not performed. Instead, a test on flammability for solids upon contact with air was conducted (see below or IUCLID Section 4.13).

Autoflammability:

Up to about 400 °C no exothermic reaction of the sample was observed.

Flammability:

Because of the result of the preliminary test, cesium iodide is considered non flammable. No flammability in contact with water and no pyrophoric properties are expected for cesium iodide.

Explosiveness:

As the sample was neither shock sensitive nor thermally or friction sensitive, according to the criteria of the EU Method A.14, cesium iodide is not representing an explosive hazard and has not to be considered to present a danger of explosion.

Oxidising properties:

The test on oxidizing properties of cesium iodide was perfomed according to the EU Method A.17. The highest burning rate of 3.28 mm/s was obtained with the mixture of 10 % test item : 90 % cellulose. This rate was definitely lower than the highest rate of the reference mixtures (3.63 mm/s). With regard to all test results the test item is assessed to have no oxidizing properties.

Stability in organic solvents:

In accordance with column 2 REACH Regulation (EC) No 1907/2006 Annex IX section 7.15, the study which examines stability in organic solvents does not need to be conduczed as the test substance cesium iodide is an inorganic substance.

Dissociation constant:

The dissociation constant was not determinable because cesium iodide is a strong electrolyte.

Viscosity:

The study which examines viscosity and is required according to REACH Regulation (EC) No 1907/2006 Annex IX section 7.17 does not need to be conducted as the test substance cesium iodide is not a liquid.