Registration Dossier

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Type of information:
experimental study
Adequacy of study:
other information
Reliability:
4 (not assignable)
Rationale for reliability incl. deficiencies:
other: secondary source from the IUCLID dataset.

Data source

Reference
Reference Type:
secondary source
Title:
IUCLID dataset
Author:
WP Mannheim GmbH
Bibliographic source:
substance 81-84-5

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 301 D (Ready Biodegradability: Closed Bottle Test)
GLP compliance:
not specified
Remarks:
secondary source

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
same with section 1.1-1.4

Study design

Oxygen conditions:
aerobic
Inoculum or test system:
other: Greenhouse sand
Details on inoculum:
no data
Duration of test (contact time):
28 d

Results and discussion

% Degradation
Value:
88
Details on results:
ready biodegradable

Applicant's summary and conclusion

Conclusions:
ready biodegradable