Registration Dossier

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin irritation / corrosion
Remarks:
in vitro
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study completed to approved methodology by a cGLP laboratory.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2010

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method B.4 (Acute Toxicity: Dermal Irritation / Corrosion)
Deviations:
no
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

In vivo

Results
Irritation parameter:
other: Direct MTT reduction
Basis:
other:
Time point:
other: 15minutes
Score:
ca. 56.7
Max. score:
100
Reversibility:
no data
Remarks on result:
other: in vitro study

Applicant's summary and conclusion

Interpretation of results:
not irritating
Remarks:
Migrated information Criteria used for interpretation of results: EU