Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Experimental starting date: 22 September 2020. Experimental completion date: 28 September 2020
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
assessment report
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - HPLC Method)
Deviations:
no
Principles of method if other than guideline:
HPLC method, designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.
GLP compliance:
yes (incl. QA statement)
Remarks:
This study has been reviewed by the Quality Assurance Unit of Covance, and the report accurately reflects the raw data.
Type of method:
HPLC method
Specific details on test material used for the study:
Identification: ALKENES, C15-18 ALPHA-, SULFURIZED
CAS number:67762-55-4
EC number:267-023-8
Appearance/Physical state:dark red/brown liquid
Lot number:720HI434
Purity:100% UVCB
Expiry / Retest date:01 July 2022
Storage conditions:room temperature, in the dark
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
> 9.4
Temp.:
30 °C
pH:
7
Details on results:
A log10 Pow result of >9.4 was taken from Harlan Study Number 41203598.

Results

PreliminaryEstimate

A log10Powresult of >9.4 was taken from Harlan Study Number 41203598.

DefinitiveTest

Typical chromatography is presented in Appendix 1 - Attachment 2 of this Summary.

Calibration

The retention times of the dead time and the retention times, capacity factors and log10 Powvalues for the reference standards are shown in the following table:

Table 2

Standard

Retention Time (min)

Capacity Factor (k')

Log10k'

Log10Pow

Injection 1

Injection 2

Mean

Thiourea (dead time)

0.898

0.896

0.897

-

-

-

Benzyl alcohol

1.070

1.071

1.070

0.193

-0.714

1.1

Naphthalene

1.752

1.752

1.752

0.953

-2.11 x 10-2

3.6

Triphenylamine

3.959

3.960

3.960

3.41

0.533

5.7

1-Phenylnonane

11.308

11.303

11.305

11.6

1.06

7.1

1-Phenylundecane

21.055

21.053

21.054

22.5

1.35

8.1

1-Phenyldodecane

29.042

29.037

29.039

31.4

1.50

8.7

1-Phenyltridecane

40.287

40.281

40.284

43.9

1.64

9.4

1-Phenyltetradecane

56.180

56.209

56.195

61.6

1.79

10.0

The calibration curve from which the sample results were taken from is shown as Attachment 1 of this Summary.

Partition coefficient of sample

The retention time, capacity factor and log10Powvalues determined for the sample are shown in the following table:

Table 3

Injection

Retention Time (min)

Capacity Factor (k')

Log10k'

Log10Pow

1

71.298

>61.6

>10.0

>1 x 1010

2

71.285

>61.6

>10.0

>1 x 1010

Overall log10Pow: >10.0
Overall partition coefficient:  >1 x 1010

Conclusions:
The partition coefficient of the test item has been determined to be greater than 1 x 10 E10, log10 Pow >10.0.
Executive summary:

The determination was carried out by the HPLC Method, using a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

The test system consisted of a high performance liquid chromatograph with an appropriate detector. A reverse phase HPLC column with a very low percentage of polar groups was used and the mobile phase contained at least 25% aqueous phase.

Conclusion

The partition coefficient of the test item has been determined to be greater than 1 x 10 E10, log10 Pow >10.0.

Description of key information

The determination was carried out by the HPLC Method, using a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

The test system consisted of a high performance liquid chromatograph with an appropriate detector. A reverse phase HPLC column with a very low percentage of polar groups was used and the mobile phase contained at least 25% aqueous phase.

Conclusion

The partition coefficient of the test item has been determined to be greater than 1 x 10 E10, log10 Pow >10.0.

Key value for chemical safety assessment

Log Kow (Log Pow):
10
at the temperature of:
30 °C

Additional information

The determination was carried out by the HPLC Method, using a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.

The test system consisted of a high performance liquid chromatograph with an appropriate detector. A reverse phase HPLC column with a very low percentage of polar groups was used and the mobile phase contained at least 25% aqueous phase.

Conclusion

The partition coefficient of the test item has been determined to be greater than 1 x 10 E10, log10 Pow >10.0.